There is much more in a ECG
MDoloris Technology™
Monitoring an innovate biological marker, the parasympathetic tone
Assess the pain and nociception
Conscious or unconscious
Improve
outcomes
Reduce
hemodynamics events
Titrate
opioids use
Our indexes
ANI - Analgesia Nociception Index
Take control of the surgical stress
Uncontrolled surgical stress is one of the source of post op pain and many other complications which hemodynamics cannot detect.
The ANI offer a continuous and noninvasive measures of the sympathetic/parasympathetic balance from 2 years old to elderly, which potentially leads to a more hemodynamic stability during anesthesia, less post-operative pain and better and faster recovery.
NIPE - Newborn Infant Parasympathetic Evaluation
Measuring comfort of new lives
Many of the 15+ million premature babies born every year face multiple painful procedures during their stay in NICU.
The NIPE (Newborn Infant Parasympathetic Evaluation) was designed to improve newborn’s comfort and stay in the NICU by measuring their parasympathetic tone, allowing the medical team to take better decisions to control nociception and improving their development.
PTA - Parasympathetic Tone Activity
Giving a voice to our pets
The absence of direct communication with animals complicates the pain level evaluation.
The PTA index developed by MDoloris Technology was created to monitor animal comfort during surgery by measuring the parasympathetic tone of the ANS, helping to control nociception and anticipate analgesia needs.
ANI, NIPE & PTA values are measuring the relative parasympathetic activity of the patients
MDoloris Technology displays two indexes; the first is related to the parasympathetic activity (ANI, NIPE and PTA are the names of the indexes related to the PS activity), and the Energy, which represent the global ANS activity. The parasympathetic tone activity reflects the pain, the nociception perceived by the body, in a conscious or unconscious patient; whilst the energy level reflects the patient “physiological reactivity”, the reserves of biological signaling and mobilization of the patient’s body’s defenses (vital energy).
MDoloris Technology products are and will be available under several forms: a classic “medical monitoring devices”, a pluggable OEM or in a wearable format..
During general anesthesia, an ANI range between 50-70 relates to adequate analgesia, meaning that antinociception is adequate and that parasympathetic activity is mildly predominant over sympathetic activity.
When the ANI value falls down below 50, the occurrence of a hemodynamic response within the following 5 minutes is very likely. This information can be used to predict and avoid a hemodynamic response by increasing analgesia.